What would cause a water heater with two functional thermostats & functional electric, to stop heating water?
Posted on | April 23, 2010 | 6 Comments
My water heater has stopped heating water. Both thermostats are working and there is a good electrical current to the heater. But there is no hot water coming out of it.
Related posts:
- Replaced upper thermostat in electric water heater, and still have no hot water? We had no water coming to the house for a...
- How to remove a stuck heating element from an electric water heater? I was able to unscrew the lower heating element (using...
- Can a worn heating heating element in an electric water heater cause its circuit breaker to trip? When I reset the breaker the water heater runs for...
Related posts brought to you by Yet Another Related Posts Plugin.
Category: Uncategorized
Tags: Cause > Electric > functional > Heater > Heating > Stop > thermostats > Water > Would
Tags: Cause > Electric > functional > Heater > Heating > Stop > thermostats > Water > Would
Comments
6 Responses to “What would cause a water heater with two functional thermostats & functional electric, to stop heating water?”
Leave a Reply
April 23rd, 2010 @ 5:50 pm
Maybe the heating element inside went bad????
April 23rd, 2010 @ 6:48 pm
burned out heating element.
April 23rd, 2010 @ 7:30 pm
Replace the top heating element.
April 23rd, 2010 @ 8:19 pm
the element sounds faulty
April 23rd, 2010 @ 9:03 pm
a water heater has 5 parts to it….the tank of course then….on a std house unit it will have 2 thermostats ( top and bottom) then 2 heating elements (top and bottom)…..NOW when u first turn on a water heater power is sent to the top element heatingp the top half of the heater since that is where the hot water comes from…..now when u pull water from there the new cold water comign in goes to the bottom of the tank thru a diptube mang the bottom return on first making it run more……So most likely it is ur bottom element that has gone out but since ur going to have to open the panels to replace it might as well do both while ur at it so u wont have to do the next one in a month or two….
April 24th, 2010 @ 10:39 am
Disconnect the power, then disconnect the wires going to the heating element. Ohm it out with a meter and see if it’s open. I vote for the top one as most heaters with 2 t-stats work the top first, then the bottom…